Pas Reform
Incubators Hatchery Automation Climate Control

About Pas Reform

Pas Reform is an international company, which has specialized in the development of innovative hatchery technologies for the poultry sector since 1919.
Read more...

Latest news

Home | Products | Incubators | SmartCenter™ Information System
SmartCenter™ Information System

SmartCenter™is a dynamic web based information system from Pas Reform that gathers real-time data, to deliver unrivalled uniformity in management and operation at every level in the modern hatchery.

SmartCenter™ - at a glance

Three main program tiers provide rapid access to SmartCenter’s™ complete information system:

Hatchery Operations, to continuously monitor incubators and hatchery automation and climate control systems, and fine-tune settings to ensure that optimum incubation conditions are maintained at all times.

Hatchery Management, to support the management of key functions, ranging from track & trace, alarm management and maintenance to breed specific incubation programming.

Hatchery Analysis, to query production activities and associated information, and to produce management reports for sharing in real time for analysis and decision-making purposes.


Technical Specifications

System data

Processor Latest Pentium based CPU
Memory 8GB Compact Flash
Operating system Suse Linux 9.3

Operating console

 
Display 15-inch TFT screen
Resolution 1024 x 768; 16 million colors
Measurements (wxhxd) 640 x 1961 x 240
Input device 88 key US layout RVS keyboard incl. trackball (IP65/NEMA6)

Connections

 
1 x LAN For communication with office network and/or internet
1 x LAN For communication with a maximum of 250 SmartDrive™ user interfaces
4 x RS485 For communication with a maximum of 4 x 32 Navigator or HOM user interfaces
1 x Output  Potential free alarm contact (NC), for external buzzer, horn, etc.
6 x Inputs 6 auxiliary inputs for free use (NC), for connection to specific Hatchery Automation or Climate Control Systems, etc.
1 x modem Voice alarm message through analog modem

Installation requirements

 
Internet Fixed internet IP (ADSL or cable), with ports 2020 and 2022 forwarded to SmartCenter™
Power 230 Volt, 50/60 Hz + ground
Cables To Navigator or HOM: 3 x 2 x 0.34 mm² shielded
To SmartDrive™; cat.5 Ethernet cable
To Backup alarm: 2 x 1 mm²
Phone line Analog phone line for voice alarm message system

Security values

 
Through local internet User name + password
Through Internet User name + password, Secure SSL internet connection, Only accessible with computer with installed, SSL certificate, IP filter which can grant/deny access to SmartCenter™ web pages